All symptoms
Diagnosis

NO POUR / SLOW POUR

Faucet open, nothing (or a trickle) comes out.

4

LIKELY CAUSES — RANKED MOST COMMON FIRST

  1. 1

    EMPTY KEG

    Most common cause — confirm before chasing other issues.

    Fix
    • Tap a fresh keg; mark and return the empty.
  2. 2

    TRIPPED FOB DETECTOR

    Foam-on-Beer sensor closed after the previous keg blew.

    Fix
    • Vent the FOB and re-seat the float per manufacturer instructions.
  3. 3

    CLOSED SHUTOFF

    A ball valve in the trunk line was closed during service.

    Fix
    • Walk the line from keg to tower; open any closed shutoffs.
  4. 4

    FROZEN LINE / ICED COUPLER

    Glycol or cooler too cold has frozen beer in the line.

    Fix
    • Warm the affected section gently with ambient air (no torches).
    • Raise glycol setpoint to 28–30°F.

STILL NOT FIXED?

Capture temp at the faucet, applied PSI at the regulator, and a photo of the pour. Then check the spec reference or run a full line cleaning.